Key Differences Between an ASD & LASD

3 mins read

The ASD transforms traditional ‘point’ detectors into powerful aspirating systems for use in normal, harsh, dusty, wet or inaccessible spaces. The ASD can house a variety of manufacturer’s conventional or analogue addressable point (spot) detectors and is available in either a single or dual pipe configuration.

If larger area coverage is required, the LASD can be specified, which is equipped with one or two laser point (spot) detectors. Compared with a traditional smoke detector, the LASD detector is classed as ‘high sensitivity’ and is therefore capable of providing far greater area coverage.

 
ModelASDLASD
DescriptionThe ASD (aspirating smoke detector) is often referred as a ‘point in a box’ aspirating smoke detection system. It can be fitted with analogue addressable or conventional detectors.The LASD, short for ‘laser aspirating smoke detector’ is designed for the protection of risks requiring class A, B or C design sensitivity. It uses a specially designed laser point detector within a aspirated enclosure.
 

The ASD system actively draws air from the protected area through a single 8mm sampling hole in a pipe run up to 50m per pipe. Sampled air is then filtered before being analysed by conventional or analogue addressable point detectors incorporated in the fire system.

The system utilises a high performance aspirator and software configurable flow monitoring circuitry. The airflow level is displayed on a ten element bar graph that can be adjusted for high and low flow thresholds, and flow failure is reported as a device fault via relays to the loop or annunciator.

The LASD system actively draws air from the protected area through sampling holes in a pipe network of up to 100m per pipe. Sampled air is then filtered before being analysed by medium sensitivity laser spot (point) detector(s) incorporated in the system. Alarm thresholds (Alert, Action or Fire) are reported by activating functional LEDs in the display and also on board voltage-free relays.

The systems utilise a high performance aspirator and software configurable flow monitoring circuitry. Air flow is displayed on a ten element bar graph that can be adjusted for high and low flow thresholds, and flow failure is reported as a device fault via dedicated fault relays.

Sampling Pipe Length (Max)50 Metres100 Metres
Sampling Holes (Max)1 or 2
Detectors1 or 2 Conventional or Analogue Addressable Point Detectors (not supplied)1 or 2, 0.06%/m Laser Point Detectors (fitted)
 Fan speed and flow sensitivity can be individually programmed using the 2 programming buttons on the right-hand side of the ASD.

The sensitivity thresholds for each of the three alarm levels, fan speed and flow sensitivity can be individually programmed using the 2 programming buttons on the right-hand side of the LASD.

There is also a USB interface below the unit which provides a connection to a PC for system configuration.

Dimension (W x H x D)259 x 184 x 166mm
Typical Applications
  • General area protection
  • Inaccessible areas
  • Shafts and service ducts
  • Locked or security controlled areas
  • Harsh environments (wet and/or dusty)
  • Ceiling and floor voids
  • Remote sampling of ventilation ductwork
  • Hose-down areas e.g. food preparation, pharmaceutical, cleaning
  • Vandal-proof applications
  • Industrial spaces such cell sites
  • Local telecommunication exchanges
  • Air handling units
  • Smaller server rooms
  • Correctional facilities
  • Control rooms
  • Utility control hubs
  • Switch rooms
  • Railway signal hubs
  • Storage facilities Cabinets
  • Hazardous areas
  • Substations
  • Small telecom and IT facilities
  • Underground stations
Part Code

EF-ASD1

EF-ASD2

EF-LASD1

EF-LASD2

    Contact Eurofyre

    SecuriSmoke ASD 2000 for Warehouses

    30th April 2026

    SecuriSmoke ASD 2000 for Warehouses

    Warehouses are essential facilities in supply chains, used to store goods before they are distributed. These large buildings support retail, logistics and manufacturing operations, often holding high volumes of stock in racking systems designed to maximise space. Many modern warehouses also function as fulfilment centres, where goods are received, sorted, picked, packed and dispatched quickly […]

    Read Article
    FyreLine Resettable Linear Heat Detection for Tunnels

    24th April 2026

    FyreLine Resettable Linear Heat Detection for Tunnels

    Road tunnels are critical transport links that support daily travel and economic activity. They often carry high volumes of traffic through enclosed environments where ventilation is limited. Fire detection in tunnels is essential to protect road users, minimise disruption, and support safe evacuation and emergency response. Early and reliable detection allows operators to respond quickly, […]

    Read Article
    • FyreLine Linear Heat detection
    • Crisis Emergency Voice Communication
    • Xenos Wireless Fire Detection

    Eurofyre is proud to supply its own brands to the fire detection and safety market. All of our products are high quality, extremely reliable and cost-effective.

    Sales & Technical Support

    Eurofyre Sales and Technical Support

    Accreditations

    ISO 9001
    UKAS Management System
    Fire Industry Association
    British Chamber of Commerce